Uninterruptable Power Supplies (UPS) provide vital backup power supply for mission critical applications and ensure the continuity of system and data center operation. When a UPS operates during a power outage, the batteries provide DC power that maintains inverter operations to support critical loads. Studies have shown that data loss from power issues is often greater than from virus attacks. IDC Research found that 33% of all server failures are due to power problems. As the importance of a reliable UPS solution for critical loads grows, it becomes increasingly crucial to safeguard against battery failure.
After a UPS is in operation, the UPS battery is the heart of the UPS in terms of availability and reliability. According to some studies, around 60% of datacenter operation downtime is caused by battery failure. Hence the continuity of battery operation is essential to UPS service availability. To ensure operation continuity, Delta UPSs are equipped with intelligent battery management to safeguard the battery and prolong UPS lifespan.
The following points demonstrate the importance of battery management:
Overcharge and deep discharge protection
Overcharging the battery can result in the battery drying out, while deep discharge may shorten your battery life. Users can set the auto discharging time to prolong battery life
Battery Temperature Compensation
The temperature compensation function can monitor battery temperature continuously and maintain an optimal temperature to extend the UPS battery life and achieve maximum performance.
Continuous Battery Monitoring
The auto or manual battery tests can be performed to detect any performance issues or problems in advance. The UPS LCD/LED panel shows the battery’s condition and its capacity in percentage format. The UPS alarm beeps to signal a remaining battery capacity warning while the UPS is in battery mode.
Remote Management
The UPS can connect to a LAN network with an SNMP card or UPSentry 2012 and InsightPower Manager Software to access and display vital information such as battery status, battery measurement, battery cabinet and replacement date on remote workstations. The easy management functionality can prevent premature battery failure, and enhance its service life and reduce battery investment.
Precautions for Battery Installation and Maintenance
In addition to using the Intelligent Battery Management system to detect malfunctions, users should take the following precautions for battery installation and regular maintenance:
- Only use the same type of batteries from the same supplier. Never use old, new, and different Ah batteries at the same time.
- The number of batteries must meet the UPS requirement.
- Do not connect the batteries in reverse.
- Keep the batteries away from fire. A battery may explode.
- The battery can present the risks of electrical shock and short circuiting the current.
- When a UPS is running for the first time, charge the UPS for at least 6-8 hours to ensure the batteries are fully charged before operation.
- Check the battery pack condition upon receiving it from the supplier to avoid any damage from expansion, collision, or leakage.
- Store the batteries in a cool and dry location.
- Avoid installing the batteries near the server room heat spot.
- Fasten the screws when connecting the batteries.
- The best temperature for battery operation is between 19°C to 22°C.
- Conduct regular maintenance.
Without a good maintenance plan or management system, batteries may fail much earlier than you expect. Delta’s innovative Intelligent Battery Management system detects battery failures in advance to protect the continuous operation of critical applications. Maximize the reliability and optimal performance of your UPS and minimize your UPS battery investment.
back
Empower Your Data Center with Delta’s InfraSuite Manager
What high-density, mission critical data centers should look for in a compact UPS
SmartNode prefabricated datacenters from Delta enable rapid edge computing deployments for 5G and the Internet of Things
The evolution of data center cooling
Modularity as a Requirement for ICT Infrastructure Engineering Systems
Efficient Management of the Data Center’s Engineering Infrastructure
The Pros and Cons of Lithium-Ion Batteries for Data Centers
The IoT is pushing data centers to the edge
The Building of a LEED-Certified Green Data Center
Quickly Enabling DCIM to Optimize Your Data Center Operation
Prefabricated Data Centers as a Global Trend
Data center power and cooling strategies for increasing rack power density
Beyond PUE: the role of DCIM in a data center
Understanding the role of DCIM in modern data centers — Bringing DCIM to the next level
Understanding the role of DCIM in modern data centers
Powering Competitiveness in TV and Broadcasting
Modular data centers: Faster, more flexible and more energy-efficient in the data centers
Powering Competitiveness in Oil and Gas
Modular Data Centers: System Architecture and Benefits
Powering Competitiveness in Datacenters
Modular Data Centers: The Rise and the Advantages
Uninterruptible Power Supplier for the Healthcare Application
Overview of Green Energy Strategies and Techniques for Modern Data Centers
Uninterruptible Power Supplies in Banking and Finance Sectors
Centralized UPS and Distributed UPS: A Comparison
Three-phase UPS Topology and Efficiency Enhancement
How to use green cooling solutions to construct a more eco-friendly datacenter
How can Datacenter Infrastructure Management (DCIM) Benefit Your Business?
How UPS and datacenter design adapts to the challenges in the era of Big Data
Datacenter Efficiency and PUE Measurement
Safeguard UPS Battery to Ensure the Continued Operation of Critical Loads
How Modular Design Addresses the Demand for High Availability and Right-sizing of Datacenters?
How does a Centralized UPS Management System improve your efficiency?
top